Features
  • Supports up to 23 Engineering Units (including one User Defined)
  • Two programmable Totalizers (main and pilot) indicate total liquid volume
  • Programmable High and low Flow Alarm limits with preset delay interval
  • Programmable High and low Temperature Alarm limits with preset delay interval (optional)
  • Two sets of user programmable optically isolated outputs
  • User selectable (via jumpers) analog 0-5 Vdc or 4-20mA flow and temperature (optional) outputs
  • Flow Pulse output (3.3Vdc CIMOS)
  • Digital Interface (RS-232 or RS-485)
  • Multi-Drop Capability of up to 256 units (RS-485 option)
  • Extensive Self Diagnostic with LCD (optional) indication
  • Local key pad and 2x16 characters LCD display with adjustable back light (optional)
  • Enclosure weather tight to IP65 standards
  • Free AALBORG configuration and calibration software (RS-232/RS-485)

Specifications

FLOW MEDIUM Please note that PWE Flow Meters are designed to work only with liquids. Never try to measure flow rates of dry gas.

CALIBRATIONS Performed at standard conditions [14.7 psia (101.4 kPa) and 70�F (21.1�C)] unless otherwise requested or stated.

VISCOSITY Calibrated to 1 cSt (water). Meters with display can be used for fluids up to 50 cSt with field calibration (maximum flow range may be affected).

ENVIRONMENTAL (PER IEC 664) Installation Level II; Pollution Degree II.

FLOW ACCURACY (INCLUDING LINEARITY) 1% of FS

REPEATABILITY 0.25% of full scale.

FLUID TEMPERATURE MEASUREMENT RANGE* -10 to 70 �C

TEMPERATURE ACCURACY (INCLUDING LINEARITY)* �0.5 �C

FLOW RESPONSE TIME approximately 1 seconds (above 10% of full scale flow), approximately 2 seconds (below 10% of full scale flow)

MAXIMUM PRESSURE 10 bar (150 psi)

MAXIMUM PRESSURE DROP 1.4 bar (20 psi) at 132.5 L/min flow. See Table IV for pressure drops associated with various models and flow rates.

FLUID AND AMBIENT TEMPERATURE 14�F to 160�F (-10�C to 70�C)

OUTPUT SIGNALS�Power consumption:�Linear 0-5 Vdc (3000 ohms min load impedance)�Linear 4-20 mA (500 ohms maximum loop resistance)�Maximum noise 20mV peak to peak (for 0-5 Vdc output)�Flow Pulse Output: 3.3 Vdc amplitude (3000 ohms min load impedance)

OPTICALLY ISOLATED OUTPUTS UCE @ 40Vdc, ICE @ 150 mA

FLOMETER INPUT POWER 11 to 26 Vdc, 100 mV maximum peak to peak output noise�Power consumption:�+12Vdc (150 mA maximum)�+24Vdc (100 mA maximum)Circuit board have built-in polarity reversal protection, 300mA resettable fuse provide power input protection.

COMMUNICATIONS PARAMETERS (RS-232/RS-485) Baud rate: .................... 9600 baud Stop bit: ....................... 1 Data bits: ...................... 8� arity: .......................... None Flow Control: ............... None

DISPLAY* Optional local 2x16 characters LCD with adjustable backlight (2 lines of text).

KEY PAD* Optional 4 push button key pad.

CE COMPLIANCE EMC Compliance with 89/336/EEC as amended.Emission Standard: EN 55011:1991, Group 1, Class AImmunity Standard: EN 55082-1:1992(* - optional feature)