List of Products from this Category

A figure promotion likely to promote products for their business.

High-Purity Four-Port Shut-Off Valve - 300 Bar - One Inlet

The DruvaPUR 20 m³ Range high-purity low flow four-port stainless steel diaphragm shut-off valve is used in supply systems handling pure, inert, flammable, oxidising, corrosive, and toxic gases and gas mixtures up to a maximum purity of 6.0.
Optimise your gas management with the Druva high-purity four-port shut-off valve, engineered for seamless performance in high-pressure environments up to 300 bar. Equipped with a Hastelloy/Elgiloy diaphragm tightening system, this high-purity valve ensures a reliable, leak-proof seal that enhances safety and prevents contamination. Its compact design maximises space efficiency, while its robust stainless steel construction makes it ideal handling pure, inert, and flammable gases.
A figure promotion likely to promote products for their business.

High-Purity Four-Port Shut-Off Valve - 300 Bar - Three Inlets

The Druva 20 m³ Range high-purity low-flow four-port metal diaphragm shut-off valve is used in supply systems handling pure, inert, flammable, oxidising, corrosive, and toxic gases and gas mixtures up to a maximum gas purity of 6.0.
The Druva high-purity four-port shut-off valve combines innovative design and rugged performance to provide unparalleled reliability in handling multiple gas sources. With a maximum working pressure of 300 bar, it is suitable for various high-pressure applications in labs, manufacturing, and industrial applications. This high-purity valve is designed with a Hastelloy/Elgiloy diaphragm tightening system to provide a robust seal to the atmosphere.
A figure promotion likely to promote products for their business.

High-Purity Packed Regulating Valves FAV 115 V/T

The DruvaPUR FAV 115 V/T packed regulating valves are ideal for extracting and adjusting corrosive gases from pressurised gas cylinders.
The Druva high-purity packed regulating valves are designed for direct mounting on cylinder valves. They are essential for processes like pressure-less polymerisations, providing consistent gas regulation. These stainless steel valves ensure prolonged durability and robust resistance to corrosion.
A figure promotion likely to promote products for their business.

High-Purity Two-Port Regulating Valve - 50 Bar

The DruvaPUR 20 m³ Range high-purity two-port regulating valve is used in supply systems handling pure, inert, flammable, oxidising, corrosive, and toxic gases and gas mixtures up to a maximum purity of 6.0.
Achieve absolute precision with the Druva two-port metal diaphragm low-flow regulating valve, expertly engineered to provide seamless control in high-purity gas applications. Featuring an Elgiloy diaphragm tightening system, it offers a leak-proof seal to the atmosphere, ensuring reliability and safety. Its compact design allows easy integration into space-constrained installations. Compliant with EN ISO 10297:2015 and suitable for explosive atmospheres, this high-purity valve is what you need for highly sensitive environments.
A figure promotion likely to promote products for their business.

High-Purity Two-Port Shut-Off Valve - 300 Bar

The DruvaPUR 20 m³ Range high-purity two-port metal diaphragm shut-off valve is used in supply systems handling pure, inert, flammable, oxidising, corrosive, and toxic gases and gas mixtures up to a maximum purity of 6.0.
The Druva high-purity two-port shut-off valve offers exceptional flow control and maximum safety. With a maximum pressure of 300 bar, it is an ideal solution for high-pressure systems handling demanding gases. Featuring an Elgiloy diaphragm tightening system, this high-purity valve provides a reliable, leak-proof seal to the atmosphere for minimised risk of contamination. With a compact design, it integrates easily into space-restricted installations.
A figure promotion likely to promote products for their business.

High-Purity Two-Port Shut-Off Valve - 40 Bar

The DruvaPUR 20 m³ range middle flow two-port shut-off valve is designed for safely handling high-purity, inert, flammable, and oxidising gases, with a maximum working pressure of up to 40 bar (600 psi).
Unlock the power of precision with the Druva high-purity two-port shut-off valve. It is engineered to handle high flow rates with ease and deliver seamless performance across various gas systems. With a Hastelloy diaphragm, this high-purity valve provides permanent technical tightness, ensuring a leak-proof seal and preventing contamination. This diaphragm shut-off valve is also oxygen-compatible and approved according to ISO 10297, meeting the strictest safety requirements for use in explosive environments (EX-zones 1 & 2).
A figure promotion likely to promote products for their business.

High-Purity Two-Port Shut-Off Valve - 50 Bar

The DruvaPUR 20 m³ Range two-port metal diaphragm shut-off valve is used in supply systems handling pure, inert, flammable, and oxidising gases and gas mixtures up to a maximum purity of 6.0. It is not usable for corrosive and toxic gases.
Engineered for critical applications, the Druva high-purity two-port shut-off valve ensures flawless performance and unparalleled reliability. It supports a maximum pressure of 50 bar and ensures contamination-free operation. This high-purity valve delivers a high level of safety and reliability, ensuring long-lasting, leak-proof performance for ultra-pure applications.
A figure promotion likely to promote products for their business.

Lab System High-Purity Combination Valve

The DruvaPUR Lab System high-purity combination valve, an optional component for Integrated or Modular Lab Versions, is suitable for gas supply systems in laboratories handling inert, flammable, oxidising, and corrosive gases, up to purity grade 6.0.
Experience dependable performance with the Druva Lab System high-purity combination valve, where safety meets precision at every turn. Its compact design integrates both shut-off and regulating functions in a single valve, saving valuable space while offering precise control. The Hastelloy diaphragm offers reliable sealing to the atmosphere for leak-proof integrity. Designed and approved in accordance with EN ISO 10297, this high-purity valve guarantees compliance with international safety standards.
A figure promotion likely to promote products for their business.

Lab System High-Purity Regulating Valve

The DruvaPUR Lab System high-purity regulating valve, an optional component for Integrated or Modular Lab Versions, is suitable for gas supply systems in laboratories handling inert, flammable, oxidising, and corrosive gases, up to purity grade 6.0.
Maximise safety and efficiency with the Druva Lab System high-purity regulating valve. It offers exceptional leak-proof performance with its O-ring seal to ensure reliable operation. Its compact design makes it ideal for space-conscious laboratories. This high-purity valve is compliant with ISO 10297 standards to guarantee the highest level of safety and quality for demanding applications.

Testimonial Image

Enrich your scientific journey through our innovative products, delve into cutting-edge services, and unlock the potential for groundbreaking research. Experience excellence at every stage with IT Tech.

Customer Care Team
Typically replies in a few hours
Customer Care Team
Hi there
How can i help you today?
WhatsApp logo in green with white phone icon inside speech bubble
Start Whatsapp Chat
WhatsApp logo in green with white phone icon inside speech bubble