SPINMASTER Research-Grade FFC NMR Relaxometer
Research-grade FFC NMR relaxometer for multi-nuclear NMRD profiling up to 40 MHz.
Stelar
Description
A research-grade Fast Field Cycling NMR relaxometer that measures T1 and T2 relaxation from a few kHz up to 40 MHz. It comes in 1 T, 0.5 T wide-bore and dual-magnet DUO configurations, with multi-nuclear capability and samples up to 26 mm.
Research-Grade Fast Field Cycling NMR Relaxometry
The SPINMASTER is Stelar's research-grade Fast Field Cycling (FFC) NMR relaxometer. It measures how the longitudinal spin-lattice relaxation time (T1) depends on magnetic field strength, and it can also measure transverse spin-spin relaxation (T2).
It measures relaxation times from a fraction of a millisecond to several seconds. Stelar's software includes a library of standard sequences, and users can program their own complex sequences and field profiles.
The SPINMASTER comes in three configurations. The 1 Tesla system reaches 40 MHz for 10 mm samples. The 0.5 Tesla Wide Bore system takes samples up to 26 mm, such as rock cores, and supports in vivo work on small animals. The dual-magnet DUO combines both, so it offers the widest choice of sample size, frequency range and measurable nuclei. Optional accessories extend what each configuration can measure.
Features
• Measures relaxation times from a fraction of a millisecond to several seconds
• Acquires NMRD profiles fully automatically
• NMRD profiles from a few kHz up to 40 MHz (1H Larmor frequency)
• Three configurations: 1 Tesla, 0.5 Tesla Wide Bore, and dual-magnet DUO
• Multi-nuclear operation: 1H, 2H, 7Li, 13C, 23Na, 31P and more, plus 19F with the optional fluorine probe
• Takes large samples up to 26 mm (1 inch), such as rock cores and small animals for in vivo studies
• T2 measurement with CPMG and FFC Spin Echo sequences
• Software with a library of standard sequences, plus sequences and field profiles you can program yourself
• Temperature control from -140 °C to +140 °C, with 0.1 °C resolution
• Low running costs, with no cryogenic gases needed
• No complex sample preparation
• Measures solids, liquids, colloids and complex mixtures
Specifications
SPINMASTER 1 Tesla
Frequency Range (1H Larmor): Few kHz – 40 MHz
Sample Diameter: 10 mm
Nuclei: 1H, 2H, 7Li, 13C (enriched), 23Na, 31P and others; 19F with optional fluorine probe
SPINMASTER 0.5 Tesla Wide Bore
Frequency Range (1H Larmor): Few kHz – 20 MHz
Sample Diameter: Up to 26 mm (1 inch)
Nuclei: 1H, 2H, 7Li, 13C, 23Na, 31P and others
Ideal For: Rock cores, in vivo small-animal studies
SPINMASTER DUO (1 T + 0.5 T Wide Bore)
Frequency Range (1H Larmor): Few kHz – 40 MHz (10 mm samples); few kHz – 20 MHz (up to 26 mm samples)
Nuclei: 1H, 2H, 7Li, 13C (enriched), 23Na, 31P and others; 19F with optional fluorine probe
All Configurations
Relaxation Time Range: < 1 ms to several seconds
Measurements: T1 (NMRD profiles), T2 (CPMG / FFC Spin Echo)
Temperature Range: -140 °C to +140 °C
Temperature Resolution: 0.1 °C
Cryogens Required: None
Optional Accessories: Variable temperature controller, high temperature probe, horizontal coil probe, fluorine probe, low-range front-end, zero-field gradient compensation
Applications & Use Cases
• Materials Science: study molecular dynamics in polymers, porous media, liquid crystals and ionic liquids
• Petrophysics & Geoscience: characterise rock cores and porous materials with the wide-bore configuration
• Biomedical Applications: characterise MRI contrast agents and proteins, and run in vivo FFC studies on small animals
• Food Science: analyse water mobility, structure and quality in food products
• Heteronuclei Studies: measure 2H, 7Li, 13C, 23Na, 31P and 19F alongside 1H
• Academic & Industrial R&D: profile solids, liquids, colloids and complex mixtures with no complex sample preparation
Frequently Asked Questions
What is the SPINMASTER?
The SPINMASTER is a research-grade Fast Field Cycling (FFC) NMR relaxometer from Stelar. It measures how T1 relaxation changes with magnetic field strength, and it can also measure T2.
What configurations are available?
There are three: SPINMASTER 1 Tesla, SPINMASTER 0.5 Tesla Wide Bore, and SPINMASTER DUO, a dual-magnet system that combines the 1 T and 0.5 T wide-bore magnets.
What frequency range does the SPINMASTER cover?
NMRD profiles run from a few kHz up to 40 MHz (1H Larmor frequency) on the 1 T and DUO systems, and up to 20 MHz on the 0.5 T Wide Bore system.
What sample sizes are supported?
The 1 Tesla system takes 10 mm samples. The 0.5 Tesla Wide Bore system takes samples up to 26 mm (1 inch), and the DUO supports both sizes.
Which nuclei can be measured?
1H, 2H, 7Li, 13C, 23Na, 31P and others. 19F can be added with the optional fluorine probe.
Can it be used for rock cores or in vivo studies?
Yes. The 0.5 Tesla Wide Bore and DUO configurations are designed for large samples such as rock cores, and for in vivo FFC NMR on small animals.
How is the SPINMASTER different from the SMARtracer™?
The SMARtracer™ is a compact benchtop system that reaches 10 MHz with 10 mm samples. The SPINMASTER is a research-grade platform that reaches 40 MHz, takes samples up to 26 mm and covers a wider range of nuclei.
Can it measure T2 as well as T1?
Yes. T2 is measured at the acquisition field with a CPMG sequence. FFC Spin Echo sequences let you study T2 across the whole field range, with some limits for very short T2 values.
What temperature range is supported?
-140 °C to +140 °C with 0.1 °C resolution.
Does it require liquid helium or other cryogens?
No. The SPINMASTER runs without cryogenic gases, which keeps operating costs low.
How can I request a quotation or demo?
Contact our team with your application and sample details, and we will recommend the right SPINMASTER configuration and send a quotation.